Energy Modeling
Here is a summary of the PRELIMINARY designs chosen for Ukiah, Sozzoni, and Lakeport. You can download a summary powerpoint of this here. Note that all this sizing info is assuming unshaded panels tilted at the latitude of the site. Or the Excel files used in the analysis: Ukiah Lakeport Sozzoni
|
System
|
PV Size (kW)
|
Micro-Hydro (kW)
|
Generator (kW)
|
Batteries (#)
|
Converter (kW)
|
|
Ukiah – Grid Tied
|
100
|
54.9
|
0
|
0
|
70
|
| Ukiah - Grid Tied + PV | 290 | 0 | 0 | 0 | 210 |
|
Ukiah – Off-Grid GHP
|
200
|
54.9
|
30
|
2,000
|
200
|
|
Lakeport Grid-Tied
|
105
|
0
|
0
|
0
|
75
|
|
Lakeport Off-Grid + propane heating
|
150
|
0
|
30
|
0
|
150
|
|
Lakeport off-Grid + GHP heating
|
150
|
0
|
30
|
1,000
|
150
|
|
Sozzoni Grid-Tied
|
125
|
0
|
0
|
0
|
90
|
|
Sozzoni off-Grid + propane heating
|
100
|
0
|
30
|
0
|
50
|
|
Sozzoni off-Grid + GHP heating
|
250
|
0
|
90
|
0
|
100
|
|
System
|
PV Size (kW)
|
Micro-Hydro (kW)
|
Converter (kW)
|
|
Ukiah – Zero Operating Cost
|
290 |
54.9
|
180 |
|
Ukiah – Revenue Generating
|
350 | 54.9 | 250 |
|
Lakeport - Zero Operating Cost
|
195
|
0 |
125
|
|
Lakeport - Revenue Generating
|
210
|
0 |
150 |
|
Sozzoni- Zero Operating Cost
|
225
|
0
|
175
|
|
Sozzoni- Revenue Generating
|
400
|
0
|
285 |
This contains energy models and associated information.
The "Data Needed" file contains the details of data needed for the HOMER Modeling.
NAEPA Model Supplementary contains information on generators and battery systems.